Terminal Relay
G6D-F4B/G3DZ-F4B
CSM_G6D-F4B_G3DZ-F4B_DS_E_5_1
Easy-to-use, Space-saving Terminal Relay
with Four-point Output
• Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H
x D)
• Each terminal circuit (with coil or contact) is independent from
one another.
• Short Bar ensures easy connection of common and adjacent
terminals.
• Provided with a terminal cover that prevents electric-shock accidents.
• Relay and MOS FET relay models are available.
• LED operation indicator.
• Built-in diode absorbs coil surge.
• Mounts either on DIN track or screws.
• Tool for easy mounting or removal of Relays provided.
• UL, CSA, and VDE certification for standard models (VDE:
G6D-F4B only).
Model Number Structure
■ Model Number Legend
G6D/G3DZ-@@
1 2
1. Terminal Form
F:
Flat type
2. Number of Relays Mounted
4B: 4
Ordering Information
■ List of Models
Output
Relay output
Contact configuration
SPST-NO × 4
Model
Rated voltage
G6D-F4B
12 VDC
G3DZ-F4B
12 VDC
24 VDC
Power MOS FET relay output
24 VDC
Note: When ordering add the rated coil voltage to the model number.
Example: G6D-F4B 24 VDC
Rated coil voltage
1
G6D-F4B/G3DZ-F4B
Specifications
■ Ratings
Coil Ratings (per G6D Relay)
Rated voltage
Rated current
Coil resistance
12 VDC
18.7 mA
720 Ω
24 VDC
10.5 mA
2,880 Ω
Must operate
voltage
70% max.
(see note 1)
Must release
voltage
10% min.
Max. voltage
130%
Power
consumption
Approx. 200 mW
Note: 1.
2.
3.
4.
The must operate voltage is 75% or less of the rated voltage if the Relay is mounted upside down.
Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±10%.
Operating characteristics were measured at a coil temperature of 23°C.
The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is
no continuous allowance.
5. The rated current includes the terminal’s LED current.
Contact Ratings (per G6D Relay)
Item
Resistive load (cosφ = 1)
Rated load
3 A at 250 VAC, 3 A at 30 VDC
Rated carry current
5A
Max. switching voltage
250 VAC, 30 VDC
Max. switching current
5A
Max. permissible capacity (reference value)
1,250 VA, 150 W
Error rate (reference value) (see note)
5 VDC, 10 mA
Note: This value is for a switching frequency of 120 times per minute.
■ Power MOS FET Relay Specifications
Input (per G3DZ Power MOS FET Relay)
Rated voltage
Operating voltage
Must operate
voltage level
12 VDC
9.6 to 14.4 VDC
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
19.2 VDC max.
Must release
voltage level
1 VDC min.
Input impedance
Rated current
2 kΩ±20%
8.0 mA±20%
4 kΩ±20%
8.2 mA±20%
Note: The rated current includes the terminal’s LED current.
Output (per G3DZ Power MOS FET Relay)
Load voltage
3 to 264 VAC
3 to 125 VDC
Load current
100 µ to 0.3 A
Inrush current
6 A (10 ms)
Note: There is no output polarity for the G3DZ.
2
G6D-F4B/G3DZ-F4B
■ Characteristics
Item
G6D-F4B
Relay output
Contact resistance (see note 2)
100 mΩ max.
Must operate time (see note 3)
10 ms max.
Release time (see note 3)
10 ms max.
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between coil and contacts.
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage (between
coil and contacts)
4,000 V (1.2 × 50 µs)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 500 m/s2
Malfunction: 100 m/s2
Endurance
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load)
100,000 operations min. (3 A at 30 VDC, resistive load) (at 1,800 operations /hr)
Ambient temperature
Operating: –25°C to 55°C (with no icing)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 65 g
Note: 1. The above values are initial values.
2. Measurement condition: 1 A at 5 VDC
3. Ambient temperature condition: 23°C
Item
G3DZ-F4B
Power MOS FET relay output
Must operate time
10 ms max.
Release time
15 ms max.
Output ON-resistance
2.4 Ω max.
Leakage current at OFF state
10 µA max. (at 125 VDC)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between input and output terminals
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 500 m/s2
Ambient temperature
Operating: –25°C to 55°C (with no icing)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 65 g
3
G6D-F4B/G3DZ-F4B
Engineering Data
Maximum Switching
Power
Endurance
DC resistive load
AC resistive load
500
300
Endurance (x104 operations)
Switching current (A)
G6D-F4B
100
30
10
5
3
0
250 VAC/30 VDC inductive load
(cosφ = 0.4, L/R = 7 ms)
1
2
3
4
5
6
7
8
9
10
Switching current (A)
Switching voltage (V)
Load Current vs.
Ambient Temperature
250 VAC/30 VDC resistive load
50
Inrush Current Resistivity: Non-repetitive
Keep the inrush current to half the rated value if it occurs repetitively.
Load current (A)
Inrush current (A. Peak)
G3DZ-F4B
Ambient temperature (°C)
Energizing time (ms)
4
G6D-F4B/G3DZ-F4B
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G6D-F4B
G3DZ-F4B
16, M3 Phillips
head screws
Mounting Dimensions
Two, 4 dia. holes or M3.5 screw holes
8.7
4
3
8
IN
2
7
6
2
1
Terminal Arrangement/
Internal Connections
(Top View)
1
5
3
4
Input side
68 max.
4
3
2
1
8
7
6
5
76±0.3
RY1 RY2 RY3 RY4
OUT
1
12
11
10
9
16
15
14
13
2
3
4
Output side
12
11
10
9
16
15
14
13
8.7
31 max.
35 max.
23±0.3
Tool for removing relays.
Note1 : Make sure that the polarity of
the input terminal is correct.
Note2 : There is no output polarity for
the G6D-F4B and G3DZ-F4B.
■ Accessories (Order Separately)
G6D-4-SB Short Bar
Applicable model
G6D-F4B
Model
G6D-4-SB
G3DZ-F4B
Relay Mounting Products
Short Bar
Name
Model
Mounting track
Applicable Terminal Relay
PFP-100N
G6D-F4B
PFP-50N
G3DZ-F4B
Model
G6D-4-SB
PFP-100N2
End plate
PFP-M
Spacer
PFP-S
Replacement Relays
Applicable Terminal
Relay
G6D-F4B
Model
G6D-1A-ASI
Rated voltage
12 VDC
24 VDC
G3DZ-F4B
G3DZ-2R6PL
12 VDC
24 VDC
Note: Error rate (P level) for the G6D-1A-ASI is 5 V at 10 mA and that
for the G6D-1A-AP is 5 V at 1 mA.
5
G6D-F4B/G3DZ-F4B
Safety Precautions
Refer to Safety Precautions for All Relays.
Wiring
Wiring
Be sure to turn OFF the power when wiring the Unit and do not touch
the charged terminals of the Unit. Otherwise, an electric shock may
result.
Pay utmost attention not to make mistakes with the polarity of the
input terminals.
Do not apply overvoltage to the input terminals. Otherwise, the Unit
may malfunction or burn.
Coil Voltage
Make sure not to impose voltage exceeding the permissible voltage
on the coil continuously.
Relay Models
Do not connect the Unit to loads exceeding the rated switching power
(switching voltage or current). Otherwise, faulty insulation, contact
weld, or faulty contact of Relays, or damage to Relays may result, or
the Relays may malfunction or burn.
Do not connect any inductive load in parallel to the coil input as
shown in the following example or power supply with a surge voltage.
Otherwise, the surge absorption diode will be damaged.
Do Not Use the Following Circuit
The life of Relays varies with the switching condition. Test the Relays
under the actual operating conditions before using the Relays within
the permissible switching frequency. The use of deteriorated Relays
may result in the faulty insulation of the Relays or cause the Relays
to burn.
Do not use the Unit in locations with inflammable gas. Otherwise, a
fire or explosion due to the heat of the Relays or sparks from the
Relays may result when they are switched.
SSR Output (Power MOS FET Relay
Model)
Do not connect the Unit to loads consuming a total current exceeding
the rated output current of the Unit. Otherwise, the output element of
the Unit may be damaged and a short or open-circuit malfunction
may result.
If the Unit is connected to a DC inductive load, connect a diode to the
Unit to protect the Unit from counter-electromotive voltage, otherwise
the counter-electromotive voltage may damage the output element
and a short or open-circuit malfunction may result.
Inductive load
G6D coil
Coil surge
absorption
diode
Handling
Do not drop, shock, or vibrate the Unit excessively. Otherwise, damage to the Unit may result or the Unit may malfunction.
Make sure that all the Relays are properly mounted before use.
Screw Tightening Torque
Tighten each terminal screw to a torque of 0.78 to 1.18N·m.
Tighten each mounting screw to a torque of 0.59 to 0.98 N·m.
■ Correct Use
Installation Environment
Mounting
Do not install the Unit in the following locations. Otherwise, damage
to the Unit may result or the Unit may malfunction.
When mounting two or more Units, reduce the current and ON duty
and provide an appropriate distance between the Units so that the
ambient temperature will not exceed 55°C.
Relay Replacement
Use the Relay Removal Tool provided with the Unit to dismount a
Relay.
Locations with direct sunlight.
Locations with an ambient temperature range not within –25°C to
55°C.
Locations with rapid temperature changes resulting in condensation
or locations with relative humidity ranges not within 45% to 85%.
Locations with corrosive or inflammable gas.
Locations with excessive dust, salinity, or metal powder.
Be sure to turn OFF the power to the Unit before replacing a Relay.
Locations with vibration or shock affecting the Unit.
When mounting a Relay, insert the Relay vertically so that the relay
terminals will come in contact with the socket contact pins properly.
Locations with water, oil, or chemical sprayed on the Unit.
Do not mount Relays that are different to one another in voltage.
Disassembly, Repair, and Modification
Do not disassemble, repair, or modify the Unit. Otherwise, an electric
shock may result or the Unit may malfunction.
Mounted Relays
Relays and SSRs cannot be mounted together.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
6